Workload scheduling under changing power limits

How do simple scheduling rules change on-time work, restart effort and estimated cost under the same changing power limit?

Record date 2026-11-01 · By Eby Mathew

Scope and inputs

Offline Python model, synthetic workload and tariffs. No live control or measured GPU/site performance.

Jobs
14
Time slots
24
Slot length
15 min
Inputs
Bundled synthetic.json

Results

SIMULATION ONLY. No real-world savings or performance claim.

On-time completion rate by policy (simulation only, synthetic inputs)
First come, first served36%
Earliest deadline first21%
Power-aware packing7%
PolicyOn-time jobsMissed deadlinesInterruptionsEnergy (kWh)Est. cost (AUD)
First come, first served5 / 147421.25$4.54
Earliest deadline first3 / 149721.25$4.51
Power-aware packing1 / 14111922.00$4.66

Power packing did not establish an advantage. Repeated interruptions increased modelled restart effort. These inputs do not prove general policy superiority.

What this cannot support

  • Synthetic workload, power trace and tariffs.
  • Perfect preservation of completed work at slot boundaries.
  • Constant active power and simplified fixed restart costs.
  • No cooling, idle-server, network, storage, battery or physical microgrid dynamics.
  • No measured customer savings, market validation or production reliability.

Validation: 10 behavioural checks passed (Python 3.12.14 on Linux). Checks model behaviour and accounting, not real-world performance.

Next experiment

Find an operator with a specific unmet need; agree an authorised dataset, competent baseline, realistic recovery assumptions, fair service metrics and a bounded feasibility study.